Lucens reactor
| Lucens reactor | |
|---|---|
Control room of the Lucens reactor in April 1968 | |
| Official name | Versuchsatomkraftwerk Lucens |
| Country | Switzerland |
| Location | Lucens, Vaud |
| Coordinates | 46°41′34.16″N 6°49′36.81″E / 46.6928222°N 6.8268917°E |
| Status | Decommissioned |
| Construction began | 1 April 1962 |
| Commission date | 10 May 1968 |
| Decommission date | 3 March 1969 |
| Owner | Nationale Gesellschaft zur Förderung der industriellen Atomtechnik |
| Operator | Energie Ouest Suisse |
| Nuclear power station | |
| Reactor type | HWGCR |
| Reactor supplier | Thermatom |
| Cooling source | Carbon dioxide |
| Power generation | |
| Units decommissioned | 1 x 6 MW |
| Nameplate capacity | 6 MW |
| External links | |
| Commons | Related media on Commons |
Suffered a nuclear accident on 21 January 1969, leading to a partial core meltdown and massive radioactive contamination | |
The Lucens reactor was an experimental nuclear power reactor built next to Lucens, Vaud, Switzerland. After its connection to the electrical grid on 29 January 1968, the reactor only operated for a year before it suffered an accident on 21 January 1969. The cause was a corrosion-induced loss of heat dispersal leading to the destruction of a pressure tube which caused an adjacent pressure tube to fail, and partial meltdown of the core, resulting in radioactive contamination of the cavern.