Sludge bulking
Sludge bulking is a microbial problem affecting solids separation in activated sludge wastewater treatment, which occurs when the sludge fails to separate out in the sedimentation tanks.
In treatment of sewage one process used is the activated sludge process in which air is passed through a mixture of sewage and old sludge to allow the micro-organisms to break down the organic components of the sewage. Sludge is continually drawn off as new sewage enters the tank and this sludge must then be settled so that the supernatant (the remaining liquid) can be separated to pass on to further stages of treatment.
The occurrence of sludge bulking prevents the solids from settling and compacting, which reduces the Return of Activated Sludge (RAS) solids concentrations, and can lead to overflow of the sludge blanket in the secondary clarifier of the wastewater treatment. Sludge bulking can be indicated using sludge settleability indicators. Activated sludge is considered as bulking if the Sludge volume index (SVI) value is above 150 mL/g. Sludge bulking can be categorized into two types: filamentous and nonfilamentous bulking. Filamentous bulking prevents activated sludge from compacting, while viscous bulking causes poor compaction and settling and may also cause foaming on the surface.
The rapid growth of microorganisms causing sludge bulking can be caused by several environmental conditions, such as low DO (Dissolved Oxygen) concentration, low F/M (Food-to-Microorganism) ratio, high concentration of low molecular weight organic acid concentration, septic wastewater or presence of hydrogen sulfide, nutrient deficiency, presence of Fats, Oils, and Grease (FOG), high sludge age or high MCRT (Mean Cell Residence Time), and low pH in the wastewater.